MaximaTech 400

MaximaTech 400

Maxima 400 Main

Model: Vertical / Upright Unit

  • Face Handpiece: Tripolar RF + Soft Laser
  • Body Handpiece: Tripolar RF + Soft Laser
  • Body Handpiece: Ultrasonic Lipo + Bionic Vacuum
  • Option: 1 Additional Handpiece
  • Certified: ISO 12845: 2003

Tripolar Radiofrequency Treatment

MaximaTech 400 is equipped with an adjustable Tripolar Radiofrequency hand piece probe (1 MHz – 10 MHz). The rapidly alternating electric currents from positive to negative in the deeper layers of the skin create targeted and controlled thermal heat within the dermis. The natural skin resistance converts electric currents to thermal energy in the dermis resulting in automatic collagen denaturation which cause skin tissues to contract. These natural processes increase cellular energy and oxygenation, skin toning and tightening, and an overall reduction of skin sag and wrinkles.

Combining Tripolar RF with Soft Laser 635 in 1 hand piece: each Tripolar RF hand-piece probe is equipped with soft laser 635. This unique combination is designed to achieve superior results in skin tightening and cellular rejuvenation to that achieved by Tripolar RF treatment alone. Soft Laser 635 accelerates the growth of collagen fibre and a substantial increase in cellular photochemical activities. These biochemical processes greatly improve the natural synthesis of cellular DNA and RNA while activating the natural elimination of metabolic cellular waste and related toxins. Soft Laser 635 greatly enhances cellular metabolism of Adenosine Triphosphate (ATP) by promoting the cell’s natural ability to repair itself.

Dual treatment in 1 hand piece allows practitioners to deliver consistent and lasting results in achieving facial and neck tightening, breasts and buttocks sculpting, cellulite and stretch marks reduction without downtime for the client.

MaximaTech 400

MaxmimaTech 400
MaximaTech 400

Ultrasonic Lipolysis Treatment

Ultrasonic Lipolysis Treatment is an innovative non surgical technology aimed at permanently reducing the number of fat cells from targeted areas of the body without the risk of negative side effects associated with conventional circumference reduction surgery. Ultrasonic Lipolysis is combined with Bio-vacuum in one hand piece for a safe and virtually painless treatment to substantially reduce the number of fat cells on the abdomen, inner and outer thighs, arms and legs without the need for incisions, medication or hospitalization.

Combining Ultrasonic Lipolysis with Bio-vacuum in 1 hand piece promotes blood circulation and metabolizes fat deposits and wastes safely and painlessly without negative side effects and without the inconvenience of downtime for the client.

How does it work ?

MaximaTech 400Bio-ultrasonic lipolysis is a non invasive procedure based on the use of a transducer probe that converts electrical energy into ultrasonic energy over a targeted area. The probe delivers short pulses of focused energy into the subcutaneous fat cells. Ultrasonic pulses cause the cells to vibrate at the frequency of 40Khz (40,000 vibrations per second). The extremely rapid vibrations disrupt the outer membrane of fat cells forcing the release of their content. This process does not compromise the integrity of blood vessels or connective tissue and does not cause any serious damage to the skin.

Treatment Session Duration

Bio-ultrasonic lipolysis require an average of 45 minutes to an hour per treatment depending on the targeted area. Daily activities can safely be resumed immediately after undergoing each Bio-ultrasonic lipolysis treatment.

What happens to the targeted fat released by the cells?

Bio-ultrasonic lipolysis is designed to target fat cells exclusively causing their triglyceride content to be dispersed into the fluid between the cells. Triglycerides are metabolized by the lymphatic system and by the body’s biological mechanisms.

What results are to be expected from Bio-ultrasonic lipolysis treatment?

Typically each Bio-ultrasonic lipolysis treatment delivers an average circumference reduction of 2cm to 3cm (1 inch) after a single treatment depending on the area treated. Optimum results are seen gradually over a span of 3 to 6 weeks following each treatment as the body clears itself of released triglycerides and of the accumulated metabolic waste.

Results achieved with Bio-ultrasonic lipolysis can be permanent when coupled with a sensible diet and moderate exercise to maintain aesthetic gains produced by the treatment. The number of treatments needed for optimum circumference reduction is best recommended by practitioners depending on circumference reductions desired by their clients.

Side effects

There are very few documented side effects related to Bio-ultrasonic lipolysis. Bruising is considered to be rare and when it does occur it is usually mild. Some redness and slight swelling may occur for a short period of time following treatment. A rare possible side effect would be the appearance of blisters in the treated area which should heal within few days.

Note: For best result clients undergoing Bio-ultrasonic lipolysis should add granulated sunflower lecithin to their diet.

IMPORTANT

Bio-ultrasonic lipolysis treatment should not be used on the face or on the backside of the client

Special options and features

MaximaTech 400 is equipped with three (3) dual treatment hand pieces and is designed to support 4 hand piece probes. You may select an additional hand piece from our probes series to customize your own MaximaTech 400 system. MaximaTech 400 is designed to support 4 handpiece probes. You may select a additional handpiece probe and customize your own MaximaTech 400 system.

Optional Hand Piece Probes

Tripolar RF Body Handpiece Tripolar RF Face Handpiece Cavitation Handpiece Bi-polar RF Body Handpiece
Tripolar RF + Laser
(Body)
Tripolar RF + Laser
(Face)
Bio-Ultrasonic Lipo
(Body)
Bi-Polar RF
(Body)
Monopolar BiPolar RF Handpiece Monopolar RF Body Handpiece Monopolar RF Face Handpiece
Bi-Polar RF
(Face)
Monopolar RF
(Body)
Monopolar RF
(Face)

Parameters / Technical Specifications

Model Name
MaximaTech 400
Display
8.4 Inch Color Touch Screen
Ultrasonic Max Output
100W
Ultrasonic Frequency
40KHz
Diode Laser Wavelength
635nm
RF Frequency
1-40Mhz, Adjustable
RF Energy
5-450J, Adjustable
Power Supply
110/220V, 50Hz/60Hz
RF Output Mode
Tri-Polar
Net Weight
45KG
Dimension
30cm X 50cm X 120cm

Shipping Container: Top Quality Padded Aluminum Case

MaximaTech 400